Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2017667
Status: Active
Facility Name: Garfield Citgo
Address: 300 W. Garfield
Chicago, IL 60609
County: Cook
Property Parcel: 20-09-416-073-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002189
Green Tag Issue Date: 2/20/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: 300 W. Garfield, LLC
Owner Address: 300 W. Garfield Blvd.
Chicago, IL 60609
Owner Status: Current Owner
Purchase Date: 11/16/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/15/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/20/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041061 300 W. Garfield, LLC Current Owner 11/16/2010
U0031867 Mohammad, Suleiman Former Owner 2/6/2004
U0029861 N E P Operating LLC Former Owner 2/6/2004
U0009782 Martin Oil Marketing, Ltd. Former Owner 6/1/1963
U0035992 Farhan, Ali Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
93-2880 5/3/1994 Removal Log 100863

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-2880 Eligible 10/28/1994 11/15/1994 $10,000
93-2880 Eligible 5/16/2012 7/13/2012 $10,000
95-1434 Eligible 5/16/2012 7/13/2012 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/1/1995
OSFM First Notify Date: 3/17/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/24/1963 Red Tag Issue Date:
Last Used Date: 6/1/1995 Fee Due: $0.00
Product Date: 7/24/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/1/1995
OSFM First Notify Date: 3/17/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/24/1963 Red Tag Issue Date:
Last Used Date: 6/1/1995 Fee Due: $0.00
Product Date: 7/24/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/1/1995
OSFM First Notify Date: 3/17/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/24/1963 Red Tag Issue Date:
Last Used Date: 6/1/1995 Fee Due: $0.00
Product Date: 7/24/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 15000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/3/1995
OSFM First Notify Date: 3/17/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/24/1963 Red Tag Issue Date:
Last Used Date: 6/1/1995 Fee Due: $0.00
Product Date: 7/24/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 3/17/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 60 Abandoned Date: 5/4/1994
Install Date: 7/27/1963 Red Tag Issue Date:
Last Used Date: 1/1/1970 Fee Due:
Product Date: 7/27/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/7/1995
OSFM First Notify Date: 3/17/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 32 Abandoned Date: 5/4/1994
Install Date: 7/27/1963 Red Tag Issue Date:
Last Used Date: 7/7/1995 Fee Due:
Product Date: 7/27/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 560 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 7/7/1995
OSFM First Notify Date: 5/21/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/27/1963 Red Tag Issue Date:
Last Used Date: 7/7/1995 Fee Due:
Product Date: 7/27/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/7/1996 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 7/1/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/2/2024 1/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/2/2024 1/2/2025
Overfill Prev Device Overfill Drop Tube Valve 11/21/2022 11/21/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/21/2022 11/21/2025
Leak Detect - Piping Sump Sensor 1/2/2024 1/2/2025
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 1/30/2024



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/7/1996 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 7/1/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/2/2024 1/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/2/2024 1/2/2025
Overfill Prev Device Overfill Drop Tube Valve 11/21/2022 11/21/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/21/2022 11/21/2025
Leak Detect - Piping Sump Sensor 11/18/2021 7/20/2022
Leak Detect - Piping Sump Sensor with positive shutdown 1/2/2024 1/2/2025
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 1/2/2024



Tank Number 10

Capacity: 4000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/7/1996 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 7/1/1995 Red Tag Issue Date: 10/24/2023
Last Used Date: 1/1/2022 Fee Due: $0.00
Product Date: 8/1/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/18/2021 7/20/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/2/2024 1/2/2025
Overfill Prev Device Overfill Drop Tube Valve 11/21/2022 11/21/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/21/2022 11/21/2025
Leak Detect - Piping Sump Sensor 1/2/2024 1/2/2025
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 1/2/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms