Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2015384
Status: Active
Facility Name: 938, Inc.
Address: 938 East St. Charles Road
Lombard, IL 60148
County: Du Page
Property Parcel: 06-04-311-044
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000638
Green Tag Issue Date: 7/15/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: 938, Inc.
Owner Address: 938 E. St. Charles Road
Lombard, IL 60148
Owner Status: Current Owner
Purchase Date: 5/3/2022
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 9/11/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/15/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040570 938, Inc. Current Owner 5/3/2022
U0039684 Lala Kala, Inc. Former Owner 10/21/2019
U0031426 Kailash Bhavan, Inc. Former Owner 6/5/2003
U0030471 Farokhian, Mathew & Russ Former Owner 12/27/2001
U0003767 Bargeway Oil Company Former Owner 1/1/1959
U0035833 Mehmood, Mujahid Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240343 (Pending)    Issue Date: 2/7/2024    Expiration Date: 4/7/2024    View NOV Form

Tanks Deficiency
1 Emergency shut-off (shear valve) must be securely mounted to a listed rigid anchor - The shear valve furtherest to the East has the U-bolt missing nut/washter off the one side
Facility Missing copies of Annual Walkthrough Inspection Report. - This form is completed by the contractor conducting you annual inspection. Please obtain and place in your compliance binder.
1, 2, 3 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
1 Stick inserted in drop tube overfill device rendering it inoperative - Remove stick.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
01-2081 Eligible 2/20/2002 3/1/2002 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 65 Abandoned Date:
Install Date: 1/1/1959 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1959

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 3/16/2023 3/16/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/8/2023 6/8/2024
Overfill Prev Device Overfill Drop Tube Valve 7/6/2022 7/6/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/21/2022 6/21/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/8/2023
Tank Steel Single Wall Precision Test (Tank) Pass 3/17/2023



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 65 Abandoned Date:
Install Date: 1/1/1959 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1959

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 3/16/2023 3/16/2028
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/8/2023 6/8/2024
Overfill Prev Device Overfill Drop Tube Valve 7/6/2022 7/6/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/21/2022 6/21/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/8/2023
Tank Steel Single Wall Precision Test (Tank) Pass 3/17/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: 4/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/15/2022 7/15/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/8/2023 6/8/2024
Overfill Prev Device Overfill Drop Tube Valve 7/6/2022 7/6/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/21/2022 6/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 6/8/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found