Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2014723
Status: Active
Facility Name: Safa Enterprises, Inc.
Address: 4601 S. Harlem Ave.
Forest View, IL 60402
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000322
Green Tag Issue Date: 3/5/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Safa Enterprises, Inc.
Owner Address: 4601 S. Harlem Ave.
Forest View, IL 60402
Owner Status: Current Owner
Purchase Date: 4/25/2005
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 10/20/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/5/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0033639 Safa Enterprises, Inc. Current Owner 4/25/2005
U0013849 Shell Oil Products Former Owner 9/7/1993
U0027449 Equilon Enterprises, LLC Former Owner 4/25/1989
U0005658 Gas City, Ltd. Former Owner 12/31/1967
U0033955 Addison & Laramie, Inc. Former Owner
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
89-0851 10/27/1989 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
89-0851 Eligible 3/25/2003 3/31/2003 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 3/6/1986 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 1/1/1984 Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 10/13/1989
OSFM First Notify Date: 10/7/1993 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/13/1989
OSFM First Notify Date: 10/7/1993 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/10/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/1989 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2024 4/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/3/2024 4/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/3/2024 4/3/2025
Overfill Prev Device Overfill Drop Tube Valve 2/17/2022 2/17/2025
Piping Fiberglass Double Wall N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/17/2022 2/17/2025
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 4/29/2021
Tank Fiberglass Double Wall Precision Test (Tank) Pass 9/11/2020



Tank Number 10

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/1989 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2024 4/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/3/2024 4/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/3/2024 4/3/2025
Overfill Prev Device Overfill Drop Tube Valve 2/17/2022 2/17/2025
Piping Fiberglass Double Wall N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/17/2022 2/17/2025
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall Precision Test (Tank) Pass 9/11/2020



Tank Number 11

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/24/1989 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/3/2024 4/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/3/2024 4/3/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/3/2024 4/3/2025
Overfill Prev Device Overfill Drop Tube Valve 2/17/2022 2/17/2025
Piping Fiberglass Double Wall N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/17/2022 2/17/2025
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall Precision Test (Tank) Pass 9/11/2020



Tank Number 12

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/30/1989
OSFM First Notify Date: 1/27/1994 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 3/5/1986 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found