Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2014046
Status: Closed
Facility Name: Meade Electric Company, Inc.
Address: 5401 W. Harrison St.
Chicago, IL 60644
County: Cook
Property Parcel:
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: U004829
Green Tag Issue Date: 8/21/2019
Green Tag Expiration Date: 7/8/2021

Owner Details

Owner Name: Meade Electric Company, Inc.
Owner Address: 625 Willowbrook Center Parkway
Willowbrook, IL 60527
Owner Status: Current Owner
Purchase Date: 12/31/1967
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/16/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 3/11/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0025903 Meade Electric Company, Inc. Current Owner 12/31/1967
U0012846 Roadway Signal Lighting Maint Former Owner 6/3/1997

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
21-0384 4/23/2021 Removal Log 00084-2021REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20210384 Eligible 7/8/2021 7/9/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/23/2021
OSFM First Notify Date: 9/3/1987 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 4/1/2019 4/1/2022
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 4/1/2019 4/1/2022
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 12/17/2020 12/17/2021
Leak Detect - Tank Automatic Tank Gauging OPW Site Sentinel 2 12/17/2020 12/17/2021
Overfill Prev Device Overfill Drop Tube Valve 4/1/2019 4/1/2022
Piping Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/1/2019 4/1/2022
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Steel Single Wall Piping Precision Test Pass 12/17/2020



Tank Number 2

Capacity: 2100 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/1/1901
OSFM First Notify Date: 10/15/1997 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/11/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/1997 Abandoned Material: Inert material mixed with portland cement
Current Age: Abandoned Date: 10/11/1989
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms