Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2012033
Status: Inactive
Facility Name: IDOT Stevenson (E26)
Address: 8630 Joliet Road
McCook, IL 60525
County: Cook
Property Parcel: 000000000
Facility Type: State
Owner Type: State
Green Tag Decal: W001798
Green Tag Issue Date: 1/7/2021
Green Tag Expiration Date: 12/31/2023

Owner Details

Owner Name: Illinois Department of Transportation
Owner Address: 2300 S. Dirksen Parkway
Springfield, IL 62764
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 12/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 1/7/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0021798 Illinois Department of Transportation Current Owner
U0007343 I Dept. of Transportation Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020231446 (Referred to Legal)    Issue Date: 6/20/2023    Expiration Date: 8/19/2023    View NOV Form

Tanks Deficiency
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Nothing completed
3 Annual line precision and mechanical line leak detector functional test not completed. - Nothing completed
Facility Electrical Does Not Comply - Safety switch should be at least 20 feet away from dispenser but no more than 100 feet away
3 Miscellaneous - Please repair tank probe and replace missing cap
Facility Missing copies of 30 day Walkthrough Inspection Report. - Nothing completed
Facility Missing copies of Annual Walkthrough Inspection Report. - Nothing completed
Facility Missing copy of emergency instructions or emergency procedures plan - Nothing completed
Facility Missing copy of written UST facility operation & maintenance plan - Nothing completed
3 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Nothing completed
3 Precision tank test required. - Nothing completed
3 Required monthly tank leak test records not available. - Nothing completed
3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Nothing completed
3 Tank monitor does not appear to function properly and requires maintenance. - Nothing completed
3 Triennial spill prevention equipment testing not completed. - Nothing completed

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
93-3292 5/14/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-3292 Eligible 10/31/1994 11/17/1994 $10,000
96-0818 Eligible 1/28/1997 2/27/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/14/1996
OSFM First Notify Date: 4/4/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 8/1/1979 Red Tag Issue Date:
Last Used Date: 4/1/1994 Fee Due: $0.00
Product Date: 1/1/1979

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4300 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/14/1996
OSFM First Notify Date: 4/4/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 1/1/1966 Red Tag Issue Date:
Last Used Date: 5/14/1996 Fee Due: $0.00
Product Date: 1/1/1966

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/28/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 5/1/1996 Red Tag Issue Date: 8/21/2023
Last Used Date: 6/20/2023 Fee Due: $0.00
Product Date: 6/1/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/7/2021 4/7/2022
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 6/9/2020 6/9/2021
Overfill Prev Device Ball Float Vent Valve 4/11/2018 4/11/2021
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/3/2019 6/3/2022
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 12/5/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 12/5/2023

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found