Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2010838
Status: Active
Facility Name: Crystal Lake Amoco
Address: 339 W. Virginia Street
Crystal Lake, IL 60014
County: McHenry
Property Parcel: 19-05-308-026
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003251
Green Tag Issue Date: 8/2/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Crystal Lake Real Estate, Inc.
Owner Address: 502 Pratt Ave., North
Schaumburg, IL 60193
Owner Status: Current Owner
Purchase Date: 11/27/2018
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 7/5/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/2/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039664 Crystal Lake Real Estate, Inc. Current Owner 11/27/2018
U0031897 Ohmshiva Corporation Former Owner 12/29/2003
U0000552 BP Products North America, Inc. Former Owner 12/29/2003
U0023834 BP Amoco Former Owner 4/13/1995
U0027493 Amoco Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
03-1685 Eligible 2/18/2004 3/1/2004 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 12/2/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 3/22/2023 3/22/2024
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/22/2023 3/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/22/2023 3/22/2024
Overfill Prev Device Overfill Drop Tube Valve 3/22/2023 3/22/2026
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 6/30/2023 6/30/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test Pass 3/22/2023



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 12/2/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 3/22/2023 3/22/2024
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/22/2023 3/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/22/2023 3/22/2024
Overfill Prev Device Overfill Drop Tube Valve 3/22/2023 3/22/2026
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/22/2023 3/22/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test Pass 3/22/2023



Tank Number 3

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 12/2/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 3/22/2023 3/22/2024
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/22/2023 3/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 3/22/2023 3/22/2024
Overfill Prev Device Overfill Drop Tube Valve 3/22/2023 3/22/2026
Piping Galvanized Steel Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/22/2023 3/22/2026
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Galvanized Steel Single Wall Piping Precision Test Pass 3/22/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found