Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2009613
Status: Active
Facility Name: 7-Eleven #32666
Address: 1156 S. York Rd.
Bensenville, IL 60106
County: Du Page
Property Parcel: 03-26-204-013
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003214
Green Tag Issue Date: 7/26/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: 7-Eleven, Inc.
Owner Address: 3200 Hackberry Road - Gas Compliance
Irving, TX 75063
Owner Status: Current Owner
Purchase Date: 1/1/1998
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 7/26/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014207 7-Eleven, Inc. Current Owner 1/1/1998
U0019212 Southland Corp Former Owner 1/1/1998
U0021382 Msp Inc An Illinois Corp Former Owner 3/1/1988
U0002992 Citgo Petroleum Corporation Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240817 (Pending)    Issue Date: 3/19/2024    Expiration Date: 5/18/2024    View NOV Form

Tanks Deficiency
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom. 175.210 h)

NOV Number: E0020240818 (Pending)    Issue Date: 3/19/2024    Expiration Date: 5/18/2024    View NOV Form

Tanks Deficiency
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain on site with other annual testing documentation.
5, 6, 7 Document that emergency shut-off (shear valves) are in proper working order - Provide documentation that annual testing of all shear valves has been conducted and passed.
Facility Facility Operation and Maintenance Plan not completed or available. - Owners and operators are required to maintain on-site a Facility Operation and Maintenance Plan. A template of the plan can be found at: https://sfm.illinois.gov/content/dam/soi/en/web/sfm/sfmdocuments/documents/oandmtemplate.pdf
5 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site.
Facility Missing copies of current testing certificates for operator training - Copies of all current Class C testing certificates shall be maintained on file on site.
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures plan shall be maintained on site for viewing and reference as necessary (See Operator Training Rules 176.645). The emergency plan template is available on the OSFM website.
Facility Missing list of designated Class A/B & C Operators - An operator list must be kept on site.
5, 6, 7 Monthly line interstitial sensor records not available. - They only have the last few month line sensor reports. There musrt be one normal report per month.
7 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
5, 6, 7 Precision line test required. - Required due to not having monthly line sensor reports.
5, 6, 7 Precision tank test required. - Required due to not having monthly tank sensor reports.
5, 6, 7 Required monthly tank interstitial sensor records not available. - They only have the last few month tank sensor reports. There musrt be one normal report per month.
5, 6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Spill buckets must be kept clean and dry.
5 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - STP sump(s) contain(s) liquid, creating alarm on ATG. Remove liquid and repair containment to prevent further liquid ingress. Repair/replace sensor(s) as necessary to clear alarm.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
98-1581 9/9/1998 Removal Log
98-1581 9/23/1998 Removal Log 4273-98

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-1581 Eligible 7/9/1998 8/3/1998 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/9/1998
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/9/1998
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/9/1998
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: 9/22/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/1/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 9/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/7/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/15/2023 6/15/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/15/2023 6/15/2024
Overfill Prev Device Overfill Drop Tube Valve 6/15/2023 6/15/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/10/2023 11/10/2026
Leak Detect - Piping Piping Sump Sensors Sump Sensor Veeder Root TLS 350 6/15/2023 6/15/2024
Spill Contain Device Double Wall Spill Bucket 6/15/2023 6/15/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/1/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 9/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/7/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/15/2023 6/15/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/12/2023 7/12/2024
Overfill Prev Device Overfill Drop Tube Valve 6/15/2023 6/15/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 11/10/2023 11/10/2026
Leak Detect - Piping Piping Sump Sensors Sump Sensor Veeder Root TLS 350 6/15/2023 6/15/2024
Spill Contain Device Double Wall Spill Bucket 6/15/2023 6/15/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/1/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 9/1/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/7/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/15/2023 6/15/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 6/15/2023 6/15/2024
Overfill Prev Device Overfill Drop Tube Valve 6/15/2023 6/15/2026
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 1/24/2024 1/24/2027
Leak Detect - Piping Piping Sump Sensors Sump Sensor Veeder Root TLS 350 6/15/2023 6/15/2024
Spill Contain Device Double Wall Spill Bucket 6/15/2023 6/15/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/10/2023 11/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/15/2023 6/15/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/10/2023 11/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/15/2023 6/15/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/10/2023 11/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/15/2023 6/15/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/10/2023 11/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/15/2023 6/15/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/10/2023 11/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/15/2023 6/15/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/10/2023 11/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/15/2023 6/15/2024

MFD Motorfuel Dispensing Forms

No Forms Found