Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2007017
Status: Active
Facility Name: Shell
Address: 6658 S. Western
Chicago, IL 60636
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001422
Green Tag Issue Date: 3/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: V-R-5 Management, Inc.
Owner Address: 3300 W. Albion Ave.
Lincolnwood, IL 607123802
Owner Status: Current Owner
Purchase Date: 5/22/2014
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 4/12/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/10/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037964 V-R-5 Management, Inc. Current Owner 5/22/2014
U0035735 True North Energy, LLC Former Owner 3/8/2010
U0013849 Shell Oil Products Former Owner 12/31/1967
U0027449 Equilon Enterprises, LLC Former Owner 1/1/1963
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020232873 (Pending)    Issue Date: 12/22/2023    Expiration Date: 2/20/2024    View NOV Form

Tanks Deficiency
7, 8, 9 Line leak detection equipment in alarm or failed test, must repair or replace.
7, 8, 9 Miscellaneous - Dispenser 3 & 7 need to be repaired
7, 8 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-0993 Eligible 10/1/2008 10/30/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7734 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/7/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7734 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/7/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1971 Red Tag Issue Date:
Last Used Date: 5/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6045 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/7/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 5/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 5181 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/7/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 5/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/7/1991
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1963 Red Tag Issue Date:
Last Used Date: 5/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/1/1988
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 7/3/1963 Red Tag Issue Date:
Last Used Date: 1/1/1988 Fee Due: $0.00
Product Date: 7/1/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/18/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 6/10/1991 Red Tag Issue Date: 4/29/2024
Last Used Date: Fee Due: $0.00
Product Date: 6/10/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/23/2021 8/23/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/3/2022 7/26/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/26/2023 7/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/26/2023 7/26/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2021 8/23/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/23/2021 8/23/2024
Leak Detect - Piping Sump Sensor 7/26/2023 7/26/2024
Spill Contain Device Single Wall Spill Bucket 8/23/2021 8/23/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 7/26/2023



Tank Number 8

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/18/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 6/10/1991 Red Tag Issue Date: 4/29/2024
Last Used Date: Fee Due: $0.00
Product Date: 6/10/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/23/2021 8/23/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/3/2022 7/26/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/26/2023 7/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/26/2023 7/26/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2021 8/23/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/23/2021 8/23/2024
Leak Detect - Piping Sump Sensor 7/26/2023 7/26/2024
Spill Contain Device Single Wall Spill Bucket 8/23/2021 8/23/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 7/26/2023



Tank Number 9

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/18/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 6/10/1991 Red Tag Issue Date: 4/29/2024
Last Used Date: Fee Due: $0.00
Product Date: 6/10/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/23/2021 8/23/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/3/2022 7/26/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/26/2023 7/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/26/2023 7/26/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2021 8/23/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/23/2021 8/23/2024
Leak Detect - Piping Sump Sensor 7/26/2023 7/26/2024
Spill Contain Device Single Wall Spill Bucket 8/23/2021 8/23/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 7/26/2023



Tank Number 10

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 5/9/1991
OSFM First Notify Date: 11/9/1992 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1902 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found