Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2006179
Status: Closed
Facility Name: A Tire County Service, Inc.
Address: 363 North Cedar Lake Road
Round Lake, IL 60073
County: Lake
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: F000186
Green Tag Issue Date: 5/3/2004
Green Tag Expiration Date: 12/31/2007

Owner Details

Owner Name: A Tire County Service, Inc.
Owner Address: 363 North Cedar Lake Road
Round Lake, IL 60073
Owner Status: Current Owner
Purchase Date: 1/1/1986
Type of Financial Responsibility: Commercial Insurance and Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2004

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/20/2005 12/31/2007

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0000122 A Tire County Service, Inc. Current Owner 1/1/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0697 6/30/2011 Removal Log 00280-2011REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
90-1275 Eligible 6/22/2006 7/24/2006 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 5000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/30/2011
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 6/28/2006 Fee Due: $0.00
Product Date: 1/1/1974

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/26/2002 6/26/2003
Corrosion Prot - Tank Lining Materials Internal 3/14/2002 3/14/2007
Leak Detect - Piping Pressurized Line Leak Detection 5/3/2004 5/3/2005
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/30/2011
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 6/28/2006 Fee Due: $0.00
Product Date: 1/1/1974

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/26/2002 6/26/2003
Corrosion Prot - Tank Lining Materials Internal 3/14/2002 3/14/2007
Leak Detect - Piping Pressurized Line Leak Detection 5/3/2004 5/3/2005
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/30/2011
OSFM First Notify Date: 3/26/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 6/28/2006 Fee Due: $0.00
Product Date: 1/1/1974

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 6/26/2002 6/26/2003
Corrosion Prot - Tank Lining Materials Internal 3/14/2002 3/14/2007
Leak Detect - Piping Pressurized Line Leak Detection 5/3/2004 5/3/2005
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/30/2011
OSFM First Notify Date: 7/1/2011 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1977 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found