Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2005558
Status: Active
Facility Name: 2401 Inc & OFGD Inc
Address: 2401 W. Lincoln Hwy
Olympia Fields, IL 60461
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002944
Green Tag Issue Date: 1/9/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: 2401, Inc. & OFGD, Inc.
Owner Address: 2401 W. Lincoln Hwy.
Olympia Fields, IL 60461
Owner Status: Current Owner
Purchase Date: 1/5/2007
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/2/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/9/2024 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036848 2401, Inc. & OFGD, Inc. Current Owner 1/5/2007
U0034130 Nadiakaliyal, George Former Owner 5/1/2006
U0031956 VK Petro, Inc. Former Owner 10/1/2003
U0027449 Equilon Enterprises, LLC Former Owner 5/27/1999
U0013849 Shell Oil Products Former Owner 12/31/1967
U0034375 2401, Inc. Former Owner
U0030062 Sandburg Motel Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
00-2157 11/8/2000 Removal Log 01489-2000REM
93-0015 12/23/1992 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-1586 Eligible 7/20/1998 8/25/1998 $10,000
00-2157 Eligible 7/27/2001 8/10/2001 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 9438 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/8/2000
OSFM First Notify Date: 3/25/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 11/7/2000 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 9438 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/8/2000
OSFM First Notify Date: 3/25/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1969 Red Tag Issue Date:
Last Used Date: 11/7/2000 Fee Due: $0.00
Product Date: 1/1/1969

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 7734 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/8/2000
OSFM First Notify Date: 3/25/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 11/7/2000 Fee Due: $0.00
Product Date: 1/1/1970

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/23/1992
OSFM First Notify Date: 3/25/1986 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 3/1/1992 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 12/23/1992
OSFM First Notify Date: 3/25/1986 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/1/1985 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/25/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 6/15/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/4/2024 1/4/2027
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2024 4/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 4/10/2024 4/10/2025
Overfill Prev Device Ball Float Vent Valve 11/14/2023 11/14/2026
Overfill Prev Device Overfill Drop Tube Valve 4/10/2024 4/10/2027
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/10/2024 4/10/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 4/10/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 8/8/2023



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/25/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 6/15/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/4/2024 1/4/2027
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/10/2024 4/10/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 4/10/2024 4/10/2025
Overfill Prev Device Ball Float Vent Valve 11/14/2023 11/14/2026
Overfill Prev Device Overfill Drop Tube Valve 4/22/2021 4/10/2024
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/10/2024 4/10/2027
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 4/10/2024
Tank Fiberglass Double Wall Precision Test (Tank) Pass 8/8/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found