Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2002956
Status: Active
Facility Name: Westside Maintenance Facility
Address: 1203 Cedarwood Dr
Joliet, IL 60432
County: Will
Property Parcel:
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: X004471
Green Tag Issue Date: 9/20/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: City of Joliet
Owner Address: 150 West Jefferson Street
Joliet, IL 60432
Owner Status: Current Owner
Purchase Date: 1/1/1981
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/15/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/20/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0008061 City of Joliet, Current Owner 1/1/1981

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/12/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/2/2023 8/2/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/10/2024 1/10/2025
Overfill Prev Device Overfill Alarm 12/15/2021 12/15/2024
Overfill Prev Device Overfill Drop Tube Valve 12/15/2021 12/15/2024
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/15/2021 12/15/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/2/2023



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/12/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/2/2023 8/2/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/10/2024 1/10/2025
Overfill Prev Device Overfill Alarm 12/15/2021 12/15/2024
Overfill Prev Device Overfill Drop Tube Valve 12/15/2021 12/15/2024
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/15/2021 12/15/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/2/2023



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/12/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 8/2/2023 8/2/2024
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 1/10/2024 1/10/2025
Overfill Prev Device Overfill Alarm 12/15/2021 12/15/2024
Overfill Prev Device Overfill Drop Tube Valve 12/15/2021 12/15/2024
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/15/2021 12/15/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/2/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms