Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000802
Status: Closed
Facility Name: 7-Eleven #21163
Address: 803 West Rollins Road
Round Lake Beach, IL 60073
County: Lake
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: J000268
Green Tag Issue Date: 5/8/2008
Green Tag Expiration Date: 12/31/2010

Owner Details

Owner Name: 7-Eleven, Inc.
Owner Address: 3200 Hackberry Road - Gas Compliance
Irving, TX 75063
Owner Status: Current Owner
Purchase Date: 1/1/1978
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/27/2010

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/8/2008 12/31/2010

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014207 7-Eleven, Inc. Current Owner 1/1/1978

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
09-1140 10/15/2009 Removal Log 01172-2009REM
09-1140 10/14/2009 Removal Log 01172-2009REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
09-1140 Eligible 4/7/2010 5/17/2010 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/2009
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/30/1980 Red Tag Issue Date:
Last Used Date: 10/8/2009 Fee Due: $0.00
Product Date: 1/30/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Piping Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/15/2009
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/30/1980 Red Tag Issue Date:
Last Used Date: 10/8/2009 Fee Due: $0.00
Product Date: 1/30/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Piping Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/15/2009
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 1/30/1980 Red Tag Issue Date:
Last Used Date: 10/8/2009 Fee Due: $0.00
Product Date: 1/30/1980

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection
Leak Detect - Piping Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found