Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000799
Status: Closed
Facility Name: 7-Eleven Store #30100
Address: 10658 S. Ridgeland
Chicago Ridge, IL 60415
County: Cook
Property Parcel: 24-18-220-020-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002640
Green Tag Issue Date: 1/10/2023
Green Tag Expiration Date: 5/2/2024

Owner Details

Owner Name: 7-Eleven, Inc.
Owner Address: 3200 Hackberry Road - Gas Compliance
Irving, TX 75063
Owner Status: Current Owner
Purchase Date: 9/1/1983
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/10/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014207 7-Eleven, Inc. Current Owner 9/1/1983

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00371-2024REM Removal Approved / Issued 4/3/2024 4/3/2024 10/3/2024 Documents

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 4/30/2024 Removal Log 00371-2024REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/2024
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/3/2024 1/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 1/3/2024 1/3/2025
Overfill Prev Device Overfill Drop Tube Valve 3/23/2023 3/23/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/24/2020 3/24/2023
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 1/3/2024



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/2024
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/3/2024 1/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 1/3/2024 1/3/2025
Overfill Prev Device Overfill Drop Tube Valve 2/27/2023 2/27/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/24/2020 3/24/2023
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 1/3/2024



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/30/2024
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 38 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 1/3/2024 1/3/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 1/3/2024 1/3/2025
Overfill Prev Device Overfill Drop Tube Valve 2/2/2023 2/2/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/24/2020 3/24/2023
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 1/3/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found