Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000793
Status: Active
Facility Name: 7-Eleven #30110
Address: 814 Higgins Road
Park Ridge, IL 60068
County: Cook
Property Parcel: 12-02-400-059-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000010
Green Tag Issue Date: 3/5/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: 7-Eleven, Inc.
Owner Address: 3200 Hackberry Road - Gas Compliance
Irving, TX 75063
Owner Status: Current Owner
Purchase Date: 10/1/1984
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/5/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014207 7-Eleven, Inc. Current Owner 10/1/1984
U0033573 SSS Group, Inc. Former Owner 11/1/2005

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
13-0021 1/9/2013 Removal Log 01232-2012REM
13-0021 1/8/2013 Removal Log 01232-2012REM
13-0021 2/11/2013 Removal Log 00102-2013REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
89-1536 Eligible 4/12/1994 5/2/1994 $10,000
13-0021 Partial Eligible 3/14/2013 4/17/2013 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/8/2013
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 8/1/1973 Red Tag Issue Date:
Last Used Date: 9/10/2012 Fee Due: $0.00
Product Date: 8/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/7/2011 11/7/2012
Leak Detect - Piping Sump Sensor 11/7/2011 11/7/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/8/2013
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 8/1/1973 Red Tag Issue Date:
Last Used Date: 9/10/2012 Fee Due: $0.00
Product Date: 8/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/7/2011 11/7/2012
Leak Detect - Piping Sump Sensor 11/7/2011 11/7/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/8/2013
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 8/1/1973 Red Tag Issue Date:
Last Used Date: 9/10/2012 Fee Due: $0.00
Product Date: 8/1/1973

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/7/2011 11/7/2012
Leak Detect - Piping Sump Sensor 11/7/2011 11/7/2012
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/9/2013
OSFM First Notify Date: 1/30/1986 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 4/1/1977 Red Tag Issue Date:
Last Used Date: 9/10/2012 Fee Due: $0.00
Product Date: 4/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 6/12/1996
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/16/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/21/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/12/2024 2/12/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/12/2024 2/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/12/2024 2/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/18/2024 3/18/2027
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025
Spill Contain Device Single Wall Spill Bucket 3/1/2023 3/1/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/16/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/21/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/12/2024 2/12/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/12/2024 2/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/12/2024 2/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/7/2023 3/7/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/23/2024 3/23/2025
Spill Contain Device Single Wall Spill Bucket 3/1/2023 3/1/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/29/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 1/16/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/21/2013

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/12/2024 2/12/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 2/12/2024 2/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/12/2024 2/12/2025
Overfill Prev Device Overfill Drop Tube Valve 3/7/2023 3/7/2026
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025
Spill Contain Device Single Wall Spill Bucket 3/1/2023 3/1/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 550 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 2/11/2013
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/1/2023 3/1/2026
Leak Detect - Piping Sump Sensor with positive shutdown 2/12/2024 2/12/2025

MFD Motorfuel Dispensing Forms