Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2000553
Status: Active
Facility Name: Sunset Marina
Address: 13623 S. Hoxie
Chicago, IL 60633
County: Cook
Property Parcel:
Facility Type: Marina
Owner Type: Private
Green Tag Decal: Z002308
Green Tag Issue Date: 2/20/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Sunset Marina, LLC
Owner Address: 13623 S. Hoxie
Chicago, IL 60633
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/5/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Marina 2/20/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014721 Sunset Marina, LLC Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1989
OSFM First Notify Date: 1/16/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/13/2006 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/6/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/6/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/4/2023 5/4/2024
Leak Detect - Tank Automatic Tank Gauging Pneumercator TMS 3000 5/4/2023 5/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/4/2023 5/4/2024
Overfill Prev Device Overfill Drop Tube Valve 4/13/2022 4/13/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Double Wall STP/Tanktop Sump 4/13/2022 4/13/2025
Leak Detect - Piping Sump Sensor 5/4/2023 5/4/2024
Spill Contain Device Single Wall Spill Bucket 4/13/2022 4/13/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 5/4/2023



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/13/2006 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/6/2006 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/6/2006

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/4/2023 5/4/2024
Leak Detect - Tank Automatic Tank Gauging Pneumercator TMS 3000 5/4/2023 5/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/4/2023 5/4/2024
Overfill Prev Device Overfill Drop Tube Valve 4/13/2022 4/13/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Double Wall STP/Tanktop Sump 4/13/2022 4/13/2025
Leak Detect - Piping Sump Sensor 5/4/2023 5/4/2024
Spill Contain Device Single Wall Spill Bucket 4/13/2022 4/13/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 5/4/2023

Dispenser Information



Name\ID Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 4/13/2022 4/13/2025
Leak Detect - Piping Sump Sensor 5/4/2023 5/4/2024



Name\ID Gas

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Double Wall UDC Sump 4/13/2022 4/13/2025
Leak Detect - Piping Sump Sensor 5/4/2023 5/4/2024

MFD Motorfuel Dispensing Forms

No Forms Found