Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1046980
Status: Active
Facility Name: Speedway #1144
Address: 2001 Walnut Street
Oglesby, IL 61348
County: LaSalle
Property Parcel: 18-34-212-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002868
Green Tag Issue Date: 12/21/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500
Springfield, OH 45501
Owner Status: Current Owner
Purchase Date: 7/15/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/2/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner 7/15/2019
U0039647 DO NOT USE THIS OWNER ID - Speedway, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240943 (Pending)    Issue Date: 4/1/2024    Expiration Date: 5/31/2024    View NOV Form

Tanks Deficiency
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shutoff switch shall be tested annually. Perform test, complete testing form (form is available at www.sfm.illinois.gov) and maintain on site with other annual testing documentation
Facility Facility Operation and Maintenance Plan not completed or available. - Adopt and implement a written operations and maintenance plan, signed by both the owner and either a Class A or Class B Operator designated for the UST facility An Operations & Maintenance template is available on the OSFM website.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site
Facility Missing copies of current testing certificates for operator training - Copies of all current Class A/B testing certificates shall be maintained on file on site. Copies of all current Class C testing certificates shall be maintained on file on site. Go to www.sfm.illinois.gov (UST Operator Training) to find current information regarding Operator. Training requirements, including all relevant forms.
Facility Missing copy of emergency instructions or emergency procedures plan - Emergency Procedures plan shall be maintained on site for viewing and reference as necessary (See Operator Training Rules 176.645). The emergency plan template is available on the OSFM website.
Facility Missing list of designated Class A/B & C Operators - A comprehensive list of Class A / B / C Operator(s) shall be maintained on site Left Copy onsite
1, 2, 3, 4, 5, 6 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed.
Facility Submit Notification Form for Facility Information Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of an ownership/operator change.

NOV Number: E0020240987 (Pending)    Issue Date: 4/4/2024    Expiration Date: 6/3/2024    View NOV Form

Tanks Deficiency
5 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Top lid steel ring is bent making removal for inspection difficult. Repair.
5, 6 Line interstitial sensors have been raised and rendered inoperational. - Under Dispensor sensors have been raised on Dispensor 17, 17 satellite, 18, 19 and 19 satellite.
Facility Miscellaneous
Facility Missing copies of 30 day Walkthrough Inspection Report.
1, 2, 3, 4, 5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
5, 6 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - Dispensor 17, 17 satellite, 18, 19 and 19 satellite, have liquid in containment.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/17/2023 8/17/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/17/2023 8/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/17/2023 8/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 8/18/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/17/2023 8/17/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/17/2023 8/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/17/2023 8/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 8/18/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/17/2023 8/17/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/17/2023 8/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/17/2023 8/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 8/18/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/7/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/17/2023 8/17/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/17/2023 8/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/17/2023 8/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 8/18/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020



Tank Number 5

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/17/2023 8/17/2024
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/17/2023 8/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/17/2023 8/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 8/17/2023
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 8/18/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/11/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD 8/17/2023 8/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/17/2023 8/17/2024
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Overfill Prev Device Overfill Drop Tube Valve 8/17/2023 8/17/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Spill Contain Device Single Wall Spill Bucket 7/17/2023 7/17/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 8/17/2023
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 8/18/2020
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020



Tank Number 7

Capacity: 10000 Petroleum Use: None
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 8/11/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 12/13/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/7/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Piping Sump Sensor with positive shutdown
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 with SCALD
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Alarm
Piping Single Wall STP/Tanktop Sump
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 8/18/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 19S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/2/2022 8/2/2023



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2023 7/17/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/17/2023 8/17/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
1046980 Speedway #1144 Oglesby 08/10/2020 Letter Form