Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1039027
Status: Active
Facility Name: FedEx Freight, Inc.-RFD
Address: 3302 American Road
Rockford, IL 61109
County: Winnebago
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y004440
Green Tag Issue Date: 8/7/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: FedEx Freight, Inc.
Owner Address: 2200 Forward Drive, DC: 2219
Harrison, AR 72601
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 11/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/7/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037968 FedEx Freight, Inc. Current Owner
U0022799 FedEx Freight East, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 9/1/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/2/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/29/2023 6/29/2024
Leak Detect - Tank Automatic Tank Gauging Gilbarco EMC with CSLD 6/29/2023 6/29/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/29/2023 6/29/2024
Overfill Prev Device Overfill Drop Tube Valve 6/29/2023 6/29/2026
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping N/A N/A
Piping Single Wall STP/Tanktop Sump 8/21/2023 8/21/2026
Leak Detect - Piping Sump Sensor 6/29/2023 6/29/2024
Spill Contain Device Single Wall Spill Bucket 8/21/2023 8/21/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Fail 1/17/2020
Piping Fiberglass Double Wall NOV Fiberglass Systems Red Thread IIA fiberglass piping Precision Test Pass 2/4/2020

Dispenser Information



Name\ID 1/Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/21/2023 8/21/2026
Leak Detect - Piping Sump Sensor 6/29/2023 6/29/2024



Name\ID 1/Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/21/2023 8/21/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 2/Master

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/21/2023 8/21/2026
Leak Detect - Piping Sump Sensor 6/29/2023 6/29/2024



Name\ID 2/Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/21/2023 8/21/2026
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found