Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1033379
Status: Active
Facility Name: United Parcel Service Air Hub
Address: 3300 Airport Dr.
Rockford, IL 61109
County: Winnebago
Property Parcel:
Facility Type: Airport
Owner Type: Private
Green Tag Decal: X003021
Green Tag Issue Date: 3/21/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: United Parcel Service Inc
Owner Address: 3300 Airport Dr.
Rockford, IL 61109
Owner Status: Current Owner
Purchase Date: 8/16/1994
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/26/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0025298 United Parcel Service Inc Current Owner 8/16/1994
U0015404 United Parcel Ser Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/27/1995 Abandoned Material:
Current Age: 29 Abandoned Date:
Install Date: 8/29/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/20/1994

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/13/2023 9/13/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/13/2023 9/13/2024
Overfill Prev Device Overfill Drop Tube Valve 9/23/2021 9/23/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/23/2021 9/23/2024
Leak Detect - Piping Sump Sensor 9/13/2023 9/13/2024
Spill Contain Device Single Wall Spill Bucket 9/23/2021 9/23/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 9/23/2021



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Jet A CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 11/7/1997 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 9/23/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/23/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found