Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1031096
Status: Active
Facility Name: Jacks Amoco
Address: 535 East Lincoln Highway
Hinckley, IL 60520
County: De Kalb
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002207
Green Tag Issue Date: 1/11/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Jack & Jinas Enterprise, Inc.
Owner Address: 535 East Lincoln Highway
Hinckley, IL 60520
Owner Status: Current Owner
Purchase Date: 9/15/1992
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/18/2023

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/11/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0020409 Jack & Jinas Enterprise, Inc. Current Owner 9/15/1992

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/24/1992 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 9/15/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/7/2022 9/7/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/31/2023 8/31/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/31/2023 8/31/2024
Overfill Prev Device Overfill Drop Tube Valve 9/7/2022 9/7/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/7/2022 9/7/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 8/31/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 9/10/2019



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/24/1992 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 9/15/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/7/2022 9/7/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/31/2023 8/31/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/31/2023 8/31/2024
Overfill Prev Device Overfill Drop Tube Valve 9/7/2022 9/7/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/7/2022 9/7/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 8/31/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 9/10/2019



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/24/1992 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 9/15/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/7/2022 9/7/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/31/2023 8/31/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/31/2023 8/31/2024
Overfill Prev Device Overfill Drop Tube Valve 9/7/2022 9/7/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/7/2022 9/7/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 8/31/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 9/10/2019



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/24/1992 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 9/15/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/15/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/7/2022 9/7/2025
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/31/2023 8/31/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/31/2023 8/31/2024
Overfill Prev Device Overfill Drop Tube Valve 9/7/2022 9/7/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/7/2022 9/7/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 8/31/2023
Tank Fiberglass Single Wall Precision Test (Tank) Pass 9/10/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found