Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1029129
Status: Active
Facility Name: Thornton Oil #365
Address: 1810 N. Bloomington St.
Streator, IL 61364
County: LaSalle
Property Parcel: 33-23-413-023
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002829
Green Tag Issue Date: 4/14/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Thornton's LLC
Owner Address: 2600 James Thornton Way
Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 2/11/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/9/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/9/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thornton's LLC Current Owner 2/11/2019
U0016985 Burwell Oil Co Former Owner 2/23/2002
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240793 (Pending)    Issue Date: 3/15/2024    Expiration Date: 5/14/2024    View NOV Form

Tanks Deficiency
6 Drop tube valve or overfill alarm failed inspection. Repair or replace equipment. - Tank was red tagged due to drop tube flapper missing. Last passing date was 2/11/2020. Reinstall and test new equimpment.
Facility Electrical Does Not Comply - All Junction Boxes at the probe are open due to corrosion. Replace or repair.
Facility Miscellaneous - Disp 14 (DSL) has used absorbant towels in the ground under the dispenser, remove and keep combustable material clear
Facility Missing copies of 30 day Walkthrough Inspection Report. - Missing ATG printouts. No recent ATG data observed
Facility Missing list of designated Class A/B & C Operators - Operator list needs to be updated.
1, 2, 3, 4 Shear valve(s) not properly mounted and/or not at proper height. - Anchoring bar for the shear valves is bent, center shear valve is lower than others and does not appear to be at the proper height.
1, 2, 3, 4, 5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 11400 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/7/2023 2/7/2026
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2024 2/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/5/2024 2/5/2025
Overfill Prev Device Overfill Drop Tube Valve 2/7/2023 2/7/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2024 2/5/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/5/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/5/2024



Tank Number 2

Capacity: 11400 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/7/2023 2/7/2026
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/5/2024 2/5/2025
Overfill Prev Device Overfill Drop Tube Valve 2/24/2023 2/24/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2024 2/5/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/5/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/5/2024



Tank Number 3

Capacity: 11400 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/7/2023 2/7/2026
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2024 2/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/5/2024 2/5/2025
Overfill Prev Device Overfill Drop Tube Valve 2/24/2023 2/24/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2024 2/5/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/5/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/5/2024



Tank Number 4

Capacity: 11400 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/7/2023 2/7/2026
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2024 2/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/5/2024 2/5/2025
Overfill Prev Device Overfill Drop Tube Valve 2/24/2023 2/24/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2024 2/5/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/5/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/5/2024



Tank Number 5

Capacity: 7800 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/7/2023 2/7/2026
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2024 2/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/5/2024 2/5/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/7/2023 2/7/2026
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2024 2/5/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/5/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/5/2024



Tank Number 6

Capacity: 7800 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1991 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: 7/1/1991 Red Tag Issue Date: 3/15/2024
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/7/2023 2/7/2026
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/5/2024 2/5/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/5/2024 2/5/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/19/2024 3/19/2027
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/5/2024 2/5/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/5/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/5/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 13

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found