Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1025239
Status: Closed
Facility Name: Ronald L. Leek Trust
Address: 1924 23rd Avenue
Rockford, IL 61104
County: Winnebago
Property Parcel: 11-36-403-002
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: V005116
Green Tag Issue Date: 6/30/2020
Green Tag Expiration Date: 12/15/2021

Owner Details

Owner Name: Ronald L. Leek Trust
Owner Address: 2210 Harrison Avenue
Rockford, IL 61104
Owner Status: Current Owner
Purchase Date: 6/3/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/21/2021

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 6/30/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039777 Ronald L. Leek Trust Current Owner 6/3/2015
U0009034 Leek, Ronald Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
912506 8/5/1991 Removal Log 898-91
N/A 12/14/2021 Removal Log 01288-2021REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1991
OSFM First Notify Date: 9/14/1989 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1991
OSFM First Notify Date: 9/14/1989 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/1/1991
OSFM First Notify Date: 9/14/1989 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/14/2021
OSFM First Notify Date: 10/16/1991 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 10/16/1991 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 750 11/9/2020 11/9/2021
Overfill Prev Device Overfill Drop Tube Valve 10/8/2018 10/8/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 10/8/2018 10/8/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found