Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1024333
Status: Active
Facility Name: Liebovich Bros., Inc.
Address: 2116 Preston Street
Rockford, IL 61073
County: Winnebago
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y003884
Green Tag Issue Date: 2/8/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Liebovich Bros., Inc.
Owner Address: 2116 Preston St
Rockford, IL 61102
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 2/8/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009147 Liebovich Bros., Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
910141 1/15/1991 Removal Log 6690

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1990
OSFM First Notify Date: 6/22/1988 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1990
OSFM First Notify Date: 6/22/1988 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/1/1988
OSFM First Notify Date: 6/22/1988 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 8/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 2500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/1/1988
OSFM First Notify Date: 6/22/1988 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 8/1/1972 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1972

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 500 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1991
OSFM First Notify Date: 6/22/1988 Abandoned Material: Inert material mixed with portland cement
Current Age: 40 Abandoned Date: 1/1/1978
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1978 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/7/1990 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 10/3/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 12/20/2023 12/20/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 12/20/2023 12/20/2024
Overfill Prev Device Overfill Alarm 12/13/2021 12/13/2024
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 12/15/2021 12/15/2024
Leak Detect - Piping Sump Sensor 12/20/2023 12/20/2024
Spill Contain Device Single Wall Spill Bucket 12/13/2021 12/13/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 1/1/1991
OSFM First Notify Date: 11/7/1990 Abandoned Material: Inert material mixed with portland cement
Current Age: 28 Abandoned Date: 1/1/1971
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1971 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found