Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1010250
Status: Closed
Facility Name: Greater Rockford Airport Authority
Address: 53 Airport Road
Rockford, IL 61109
County: Winnebago
Property Parcel: 15-14-151-004
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: V001815
Green Tag Issue Date: 3/3/2021
Green Tag Expiration Date: 12/31/2022

Owner Details

Owner Name: Greater Rockford Airport Authority
Owner Address: 60 Airport Drive
Rockford, IL 61109
Owner Status: Current Owner
Purchase Date: 11/25/1947
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/21/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0006108 Greater Rockford Airport Authority Current Owner 11/25/1947
U0034232 Y.M.A., Inc. Former Owner 12/22/2006
U0013752 Vista Marketing Group Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 4/26/2023 Removal Log 00312-2023REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/9/1988
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/8/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/9/1988
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/8/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/9/1988
OSFM First Notify Date: 5/7/1986 Abandoned Material:
Current Age: 46 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/8/1988 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/26/2023
OSFM First Notify Date: 8/29/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/9/2022 Fee Due: $0.00
Product Date: 9/30/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/27/2020 8/27/2023
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/5/2021 11/5/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/29/2022 4/29/2023
Overfill Prev Device Overfill Drop Tube Valve 4/29/2022 4/29/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/21/2019 4/29/2022
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 11/5/2021



Tank Number 5

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/25/2023
OSFM First Notify Date: 8/29/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/9/2022 Fee Due: $0.00
Product Date: 9/30/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/27/2020 8/27/2023
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/5/2021 11/5/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/29/2022 4/29/2023
Overfill Prev Device Overfill Drop Tube Valve 4/29/2022 4/29/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/29/2022 4/29/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 11/5/2021



Tank Number 6

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/25/2023
OSFM First Notify Date: 8/29/1990 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 11/9/2022 Fee Due: $0.00
Product Date: 9/30/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/27/2020 8/27/2023
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 11/5/2021 11/5/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/29/2022 4/29/2023
Overfill Prev Device Overfill Drop Tube Valve 4/29/2022 4/29/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/21/2019 4/29/2022
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 11/5/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found