Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1009877
Status: Active
Facility Name: A 33 Milestone Gas & Food, Inc. II
Address: 2627 Auburn Street
Rockford, IL 61103
County: Winnebago
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y004438
Green Tag Issue Date: 6/26/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: A 33 Milestone Gas & Food, Inc. II
Owner Address: 2627 Auburn Street
Rockford, IL 61103
Owner Status: Current Owner
Purchase Date: 10/1/2012
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/5/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/26/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037279 A 33 Milestone Gas & Food, Inc. II Current Owner 10/1/2012
U0035534 Auburn Gas, Inc. Former Owner 1/29/2009
U0031532 Baker Energy, Inc. Former Owner 8/27/2003
U0003073 Clark Retail Enterprises, Inc. Former Owner 11/22/1988
U0033116 P & P Gas, Inc. Former Owner
U0029789 Clark Retail Enterprises, Inc. Former Owner
U0028787 Clark Retail Enterprises, Inc., Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
N/A 10/31/2017 Removal Log 01325-2017REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/31/2017
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 54 Abandoned Date:
Install Date: 5/1/1963 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/15/2012 2/15/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2015 2/3/2016
Leak Detect - Tank Automatic Tank Gauging Arizona Instruments Encompass
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/31/2017
OSFM First Notify Date: 5/2/1986 Abandoned Material:
Current Age: 54 Abandoned Date:
Install Date: 5/1/1963 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/1/1963

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 2/15/2012 2/15/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2015 2/3/2016
Leak Detect - Tank Automatic Tank Gauging Arizona Instruments Encompass
Overfill Prev Device Ball Float Vent Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/12/2017 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 11/3/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/8/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/30/2023 6/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/30/2023 6/30/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/30/2023 6/30/2024
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 6/30/2023 6/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2023 6/30/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2023 6/30/2024
Spill Contain Device Single Wall Spill Bucket 6/30/2023 6/30/2026
Tank Fiberglass Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 8/11/2022



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/12/2017 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 11/3/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/8/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 6/30/2023 6/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/30/2023 6/30/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/30/2023 6/30/2024
Manway At Grade Accessible Manway Accessible at Grade N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 6/30/2023 6/30/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/30/2023 6/30/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2023 6/30/2024
Spill Contain Device Single Wall Spill Bucket 6/30/2023 6/30/2026
Tank Fiberglass Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 8/11/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2023 6/30/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2023 6/30/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2023 6/30/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2023 6/30/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/30/2023 6/30/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/30/2023 6/30/2024

MFD Motorfuel Dispensing Forms