Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 1001152
Status: Active
Facility Name: Rock River Water Reclamation District
Address: 3333 Kishwaukee Street
Rockford, IL 61109
County: Winnebago
Property Parcel: 1511102003
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: X002336
Green Tag Issue Date: 9/2/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Four Rivers Sanitation Authority
Owner Address: 3501 Kishwaukee Street
Rockford, IL 61109
Owner Status: Current Owner
Purchase Date: 6/23/2021
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/22/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/2/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040607 Four Rivers Sanitation Authority Current Owner 6/23/2021
U0013007 Rock River Water Reclamation District Former Owner 5/1/1927

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
92-2995 10/22/1992 Removal Log
95-1522 7/17/1995 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
92-2995 Eligible 12/27/1993 1/14/1994 $10,000
95-1522 Eligible 1/18/1996 2/15/1996 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/17/1995
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 8/1/1982 Red Tag Issue Date:
Last Used Date: 7/1/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1995
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 8/1/1982 Red Tag Issue Date:
Last Used Date: 7/14/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/17/1995
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 8/1/1980 Red Tag Issue Date:
Last Used Date: 10/15/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/22/1992
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Water CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1901 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/22/1992
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/1/1982 Red Tag Issue Date:
Last Used Date: 8/1/1992 Fee Due: $0.00
Product Date: 8/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/22/1992
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/1/1982 Red Tag Issue Date:
Last Used Date: 8/1/1992 Fee Due: $0.00
Product Date: 8/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/22/1992
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/1/1982 Red Tag Issue Date:
Last Used Date: 8/1/1992 Fee Due: $0.00
Product Date: 8/1/1982

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 10000 Petroleum Use:
Product: Water CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 3/7/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1901 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/27/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 11/1/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/26/2023 9/26/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/26/2023 9/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/26/2023 9/26/2024
Overfill Prev Device Overfill Alarm 7/8/2022 7/8/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 7/8/2022 7/8/2025
Leak Detect - Piping Sump Sensor 9/26/2023 9/26/2024
Spill Contain Device Single Wall Spill Bucket 7/8/2022 7/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/4/2020



Tank Number 11

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/27/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 11/1/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/26/2023 9/26/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/26/2023 9/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/26/2023 9/26/2024
Overfill Prev Device Overfill Alarm 7/8/2022 7/8/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 7/8/2022 7/8/2025
Leak Detect - Piping Sump Sensor 9/26/2023 9/26/2024
Spill Contain Device Single Wall Spill Bucket 7/8/2022 7/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/4/2020



Tank Number 12

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/27/1993 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 11/1/1992 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1993

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/26/2023 9/26/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/26/2023 9/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/20/2023 10/20/2024
Overfill Prev Device Overfill Alarm 7/8/2022 7/8/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 7/8/2022 7/8/2025
Leak Detect - Piping Sump Sensor 9/26/2023 9/26/2024
Spill Contain Device Single Wall Spill Bucket 7/8/2022 7/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test Pass 8/4/2020



Tank Number 13

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/15/2008
OSFM First Notify Date: 12/13/1995 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 7/1/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Alarm
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Manhole Field Constructed
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 14

Capacity: 4000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/13/1995 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 7/1/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/26/2023 9/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/26/2023 9/26/2024
Overfill Prev Device Overfill Alarm 7/8/2022 7/8/2025
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/8/2022 7/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 15

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/22/2000 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 5/3/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/4/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Annual Prec Line Testing Suction 9/26/2023 9/26/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j 9/26/2023 9/26/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/26/2023 9/26/2024
Overfill Prev Device Overfill Alarm 7/8/2022 7/8/2025
Overfill Prev Device Overfill Drop Tube Valve 7/8/2022 7/8/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor 9/26/2023 9/26/2024
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 7/8/2022 7/8/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 9/26/2023

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms